For XP1024/XP128 Disk Array, RAID Manager supports four types of port names for host groups:

Specifying the port name without a host group: CL1-A CL1-An, where n is the unit ID if
there are multiple RAID storage systems

Specifying the port name with a host group: CL1-A-g, where g is the host group CL1-An-g,
where n-g is the host group g on CL1-A in unit ID=n

The following ports can be specified for XP12000 Disk Array/XP10000 Disk Array and
XP24000/XP20000 Disk Array:

Option

Option

Option

Basic

-

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CL5

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CL6

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CL7

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CL8

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CL9

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CLA

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CLB

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CLC

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CLD

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CLE

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CLF

rn

qn

pn

nn

mn

ln

kn

jn

hn

gn

fn

en

dn

cn

bn

an

CLG

Target ID: Defines the SCSI/fibre target ID (TID) number of the physical volume on the specified
port.

LU#: Defines the SCSI/fibre logical unit number (LU#) of the physical volume on the specified
target ID and port.

NOTE:

In case of fibre channel, if the TID and LU# displayed on the system are different

than the TID on the fibre address conversion table, then you must use the TID and LU# indicated
by the raidscan command in the RAID Manager configuration file.

MU# for Business Copy (HOMRCF): Defines the mirror unit number (0 - 2) to use the redundant
mirror for the identical LU on the Business Copy. If this number is omitted, it is assumed to be
zero (0). The cascaded mirroring of the S-VOL is expressed as virtual volumes using the mirror
descriptors (MU#1-2) in the configuration definition file. The MU#0 of a mirror descriptor is
used for connection of the S-VOL. The mirror descriptor (MU#0-2) can be used in Business
Copy and Snapshot. MU#3-63 can be used in Snapshot only.

S-VOL

P-VOL

SMPL

Feature

MU#1 - 63

MU#0

MU#3 - 63

MU#0-2

MU#3 - 63

MU#0-2

Not valid

Valid

Not valid

Valid

Not valid

Valid

Business Copy

Not valid

Valid

Valid

Valid

Valid

Valid

Snapshot

32

RAID Manager software environment