Table 86 SSB codes that are returned by raidcom delete ssid command (continued)

raidcom delete ssid

Description

Error code

Executing/
Async

Error message

SSB2

SSB1

An internal error occurred.

00EF

2ED6

Executing

CMDRJE

Call HP Technical Support.

The SSID is invalid.

3300

2ED6

Executing

CMDRJE

The specified parameter is invalid. Check the HP XP7 RAID
Manager Reference Guide.

3002

2EF3

Executing

CMDRJE

Table 87 SSB codes that are returned by raidcom add thp_pool command

raidcom add thp_pool

Description

Error code

Executing/
Async

Error message

SSB2

SSB1

LDEV number is out of rage.

0000

2E00

Async

Get Command Status

The value of pool ID is out of range.

6000

2E00

Executing

CMDRJE

The type of pool is invalid.

6001

2E00

Executing

CMDRJE

The maximum reserve ratio of V-VOL is out of range.

6002

2E00

Executing

CMDRJE

The threshold of the specified High water mark is out of range.

6009

2E00

Executing

CMDRJE

The operation cannot be done because the specified threshold
of Warning is larger than the threshold of the specified High
water mark.

600A

2E00

Executing

CMDRJE

The specified LDEV is in the state of blocked.

0009

2E10

Async

Get Command Status

The operation cannot be done because a SATA-E drive in the
state of quick formatting is in the specified LDEV.

000C

2E10

Async

Get Command Status

The specified LDEV is in the state of blocked, or not installed.

0011

2E10

Executing

CMDRJE

The pool cannot be created because there are not enough
resources (VDEV) depending on cache management devices.

0102

2E10

Async

Get Command Status

The operation cannot be performed because the pool volume
is being deleted.

600D

2E10

Async

Get Command Status

The specified operation is not supported in the current microcode
version.

8002

2E10

Async

Get Command Status

The pool is not in the status where the pool volume can be
added.

6003

2E11

Executing

/Async

CMDRJE

Get Command Status

The operation cannot be done because the power supply is
switched off.

8003

2E11

Async

Get Command Status

The command cannot be accepted. After a while, execute the
same command.

9400

2E11

Executing

CMDRJE

The specified LDEV is not installed.

0000

2E20

Async

Get Command Status

The operation cannot be performed because the memory
capacity of the shared memory (SM) is insufficient.

8103

2E21

Async

Get Command Status

The operation cannot be performed because the shared memory
(SM) is not initialized.

8106

2E21

Async

Get Command Status