Table 89 SSB codes that are returned by raidcom delete rcu_path command (continued)

raidcom delete rcu_path

Description

Error code

Executing/
Async

Error message

SSB2

SSB1

The operation cannot be done because the number of paths
becomes less than the least path number.

3101

2E23

Async

Get Command Status

The port attribute is not Initiator (MCU).

840A

2E30

Executing

CMDRJE

Command cannot be executed because the RCU identification
code of a path is invalid.

3001

2E31

Async

Get Command Status

Command cannot be executed because the serial number is not
unified in the specified path.

3101

2E31

Async

Get Command Status

The command cannot be accepted because the DKC is busy.
After a while, execute the same command.

00EE

2ED6

Executing

CMDRJE

An internal error occurred.

3005

2ED6

Async

Get Command Status

Call HP Technical Support.

The specified parameter is invalid. Check the HP XP7 RAID
Manager Reference Guide.

3002

2EF3

Executing

CMDRJE

Table 90 SSB codes that are returned by raidcom add rcu_path command

raidcom add rcu_path

Description

Error code

Executing/
Async

Error message

SSB2

SSB1

CU# of RCU exceeds the effective value.

3001

2E00

Executing

CMDRJE

Invalid product ID or path registration ID.

3005

2E00

Executing

CMDRJE

Command cannot be executed because the parameter of
specified RCU is invalid.

3008

2E00

Async

Get Command Status

Command cannot be executed because all the CU numbers in
the RCU is not unified at the path that is specified creation or
deletion.

3009

2E00

Async

Get Command Status

The value of port # on the side of RCU is invalid.

3200

2E00

Executing

CMDRJE

The CU number is out of effective range.

7100

2E00

Executing

CMDRJE

/Async

Get Command Status

The value of specified port is invalid.

8400

2E00

Executing

CMDRJE

/Async

Get Command Status

Failed to establish a path or the deletion operation. The following
factor can be thought.

3101

2E10

Async

Get Command Status

Input parameter is invalid.

Port status or the MP Blade status is in the state of abnormal.

Cable is not connected correctly.

Port is specified incorrectly.

The operation cannot be done because the microcode is being
changed.

8004

2E11

Async

Get Command Status

The command cannot be accepted. After a while, execute the
same command.

9400

2E11

Executing

CMDRJE