HP XP7 Storage User Manual

Page 276

Advertising
background image

Table 87 SSB codes that are returned by raidcom add thp_pool command (continued)

raidcom add thp_pool

Description

Error code

Executing/
Async

Error message

SSB2

SSB1

The RAID level of the specified LDEV is different with the RAID
level of others.

0015

2E31

Async

Get Command Status

There is a blocked pool volume.

0016

2E31

Async

Get Command Status

External volumes whose cache modes are different are included.

0018

2E31

Async

Get Command Status

The POOL Name is duplicated with another pool.

6001

2E31

Executing

CMDRJE

The pool cannot include volumes in different RAID levels because
the pool cannot include those volumes. Or the pool cannot

6004

2E31

Async

Get Command Status

include the RAID 1 volumes and the volumes of other RAID levels
together.

The pool cannot include both internal volumes and external
volumes because the pool is not set to Mixable.

6005

2E31

Async

Get Command Status

The usage capacity exceeds the license capacity of program
product.

9000

2E31

Async

Get Command Status

The command cannot be accepted. After a while, execute the
same command.

00EE

2EE7

Executing

CMDRJE

An internal error occurred.

FEEC

2EE7

Executing

CMDRJE

Call HP Technical Support.

Async

Get Command Status

Table 88 SSB codes that are returned by raidcom modify rcu command

raidcom modify rcu

Description

Error code

Executing/
Async

Error message

SSB2

SSB1

CU# of RCU exceed the effective value.

3001

2E00

Executing

CMDRJE

The value of least path number is invalid.

3002

2E00

Executing

CMDRJE

The value of RIO MIH time is invalid.

3003

2E00

Executing

CMDRJE

The value of Round-trip response time is invalid.

3004

2E00

Executing

CMDRJE

Invalid product ID or path registration ID.

3005

2E00

Executing

CMDRJE

Incident that is created by CU is not in the one of followings.

3007

2E00

Executing

CMDRJE

- Incident that is sent to MCU host and RCU.

- Incident that is sent to RCU.

Command cannot be executed because the parameter of
specified RCU is invalid.

3008

2E00

Async

Get Command Status

Command cannot be executed because all the CU numbers in
the RCU is not unified at the path that is specified creation or
deletion.

3009

2E00

Async

Get Command Status

The CU number is out of effective range.

7100

2E00

Executing

CMDRJE

The operation cannot be done because the microcode is being
changed.

8004

2E11

Executing

CMDRJE

The serial number, the product ID, or the SSID of the target
storage system is incorrect.

3000

2E20

Executing

CMDRJE

276 Troubleshooting

Advertising
This manual is related to the following products: