Common parameters – Vaisala AWS330 User Manual

Page 116

Advertising
background image

User's Guide ______________________________________________________________________

114 _________________________________________________________________ M211296EN-B

Common Parameters

The dialog presented in Figure 63 below contains the essential
parameters for an operational station.

1011-014

Figure 63

Common Parameters Dialog

To set the common parameters:

1. Open

menu

Settings - Parameters - Common.

2. Enter

Name for the station. Do not use spaces or special characters

in the station name.

3. Enter

station

Altitude in meters from mean sea level. This setting

is needed only if the station provides measurement for barometric
pressure.

4. Enter

Pressure Sensor Level in meters from ground. This is the

bottom flange height from ground. This setting is needed only if the
station provides measurement for barometric pressure.

5. Parameter

Battery Capacity is not used by AWS330, and has no

effect.

6. Press

Save to store the settings and close the dialog.

Advertising