- The recommended grounding resistance is 10 Ω or less for both the

grounding of lighting protection rod and for the equipment grounding.
Soil conditions (sand, rocks, and so on) and the ground resistance
measurement determine the design and construction of the grounding
system. Buried ground rods and/or buried wire can be used for the
ground network. The type and combination used depend on soil
conditions (ease of installation) and on the value of measured ground
resistance (the most effective way of reducing resistance to the
required value of 10 Ω or less). Measurements of the earth resistance
must be made at least 48 hours after rainfall.

- The connection between ground rods and the equipment frames and

copper cables should be made with appropriate compression lugs,
bolts, nuts, and lock washers.

Table 17

Examples of Soil Resistivities, Ohm-Meters

Soil Type

Median

Variation

Topsoil, loam

26

1 ... 50

Inorganic clays of high plasticity

33

10 ... 55

Silty or clayey fine sands with slight plasticity

55

30 ... 80

Fine sandy or silty clays, silty clays, clean clays

190

80 ... 300

Silty sands, poorly graded sand-silt mixtures

300

100 ... 500

Well-graded gravel, gravel sand mixtures

800

600 ... 1 000

Due to the above reasons and soil variations, the grounding accessories
must be supplied locally.