242 _________________________________________________________________ M211296EN-B

Table 74

Jumper Settings for DSI486-B

Jumper Connected

Pins

Function

1-2

Channel B RS-232 mode

X3

2-3

Channel B RS-485 mode (default)

1-2

Channel B RS-485 mode (default)

X6

2-3

Channel B RS-232 mode

X4

1-2

Channel A RS-485 line terminating resistor
active

X5

1-2

Channel B RS-485 line terming resistor active.
Do not use in RS-232 mode

The dual RS-485 module also provides an SDI-12 connection. The SDI-
12 line uses one wire for data and is limited to the maximum length of
60 meters. Figure 130 below provides a schematic wiring diagram for the
SDI-12 connection and the 12 VDC power supply for a sensor. The
jumper settings should be as shown in Figure 128 on page 241.

1006-103

Figure 130 Dual RS-485 Wiring Diagram for SDI-12 and 12 VDC

Power Supply

Simultaneously with the SDI-12, you can connect channels A and B in
the 2-wire RS-485 mode.