Alarms – Vaisala AWS330 User Manual

Page 28

Advertising
background image

User's Guide ______________________________________________________________________

26 __________________________________________________________________ M211296EN-B

Alarms

AWS330 system can be enabled to send alarm messages based on
selected observation values and technical alarms based on system and
sensor status.

The following alarm sources and limits are available:

Table 12

Alarm Sources and Types

Monitored Value

Unit

Alarm Type

Air temperature instant

°C

High limit

Air temperature instant

°C

Low limit

Wind speed max 10 min

m/s

High limit

Precipitation sum 1 hour

mm

High limit

Data logger temperature

°C

High limit

Data logger temperature

°C

Low limit

Data logger supply
voltage

VDC Low

limit

In addition, all sensor failures are reported as alarms.