Appendix B ______________________________________________________ Calculation Formulas

VAISALA ______________________________________________________________________ 275

Wind Chill (NWS 2001)

Wind chill, which is an estimate of the heat loss from an open surface, is
calculated according to the formula updated by NWS in 2001:

16

.

0

16

.

0

486

.

0

95

.

13

62

.

0

13

.

13

WS

T

WS

T

W

A

A

ch

+

+

=

where
W

Ch

=

Wind chill [

°

C]

T

A

=

Air temperature [

°

C]

WS =

Wind

speed

[m/s]

Table 114

Inputs for Wind Chill Calculation

Input Variable
Air temperature (TA)

TAAVG1M; see Table 4 on page 22

Wind speed (WS)

WSAVG2M; see Table 6 on page 24

Wet Bulb Temperature

Wet bulb temperature is calculated iteratively as follows:

First the initial estimate of wet bulb temperature is calculated with the
formula:

6.112

)

(T

P

log

-

17.62

6.112

)

(T

P

log

243.12

T

d

ws

d

ws

wet

=

Then the wet bulb temperature is iteratively re-calculated as long as
ABS(P

hit

-P

ws

(T

d

))>0.01 with the formula: