Vaisala wind vane wav151 – Vaisala AWS330 User Manual

Page 258

Advertising
background image

User's Guide ______________________________________________________________________

256 _________________________________________________________________ M211296EN-B

Vaisala Wind Vane WAV151
Table 99

Vaisala Wind Vane WAV151, Wind Direction

Property Description/Value
Measurement range at wind
speed 0.4 ... 75 m/s

0 ... 360°

Starting threshold

<0.4 m/s

Resolution ±2.8°
Damping ratio

0.19

Overshoot ratio

0.55

Delay distance

0.4 m

Table 100

Vaisala Wind Vane WAV151, General

Property Description/Value
Operating power supply

U

in

= 9.5 ... 15.5 VDC, 20 mA typical

Heating power supply

AC or DC 20 V, 500 mA nominal

Output code

6-bit parallel GRAY

Output levels

with

I

out

<+5 mA

High state > U

in

-1.5 V

with

I

out

>–5 mA

Low state < 1.5 V

Settling time after power
turn-on

<100 µs

Plug 10-PIN

MIL-C-26482 type

Cabling

10-wire cable through cross arm

Recommended connector at
cable end

SOURIAU MS3116F12-10P

Operating temperature with
heating

-50 ... +55 °C (-58 ... +131 °F)

Storage temperature

-60 ... +70 °C (-76 ... +158 °F)

Material

Housing

AlMgSi, gray anodized

Wave

Alsi 12 anodized

Dimensions

300 (h) Ч 90 (Ш) mm

Swept radius of vane

172 mm

Weight 660

g

Table 101

Vaisala Wind Vane WAV151, Test Compliance

Property Description/Value
Wind tunnel tests

ASTM standard method D5366-93 (for starting
threshold, distance constant, transfer function)

Exploratory vibration test

MIL-STD-167-1

Humidity test

MIL-STD-810E, Method 507.3

Salt fog test

MIL-STD-810E, Method 509.3

Complies with EMC standard EN61326-1:1997 + Am1:1998; Am2:2001;
Generic Environment

Advertising