Changing Sensor Configuration

If standard AWS330 sensors are added to or existing sensors are removed
from the configuration, sensor management parameters should be
changed accordingly.

The following parameters are used to control sensor configuration:

1012-169

Figure 88

Changing Sensor Configuration

Table 40

Sensor Selection Parameters

Set Name

Parameter Name Sensor

General settings HMP155

Air temperature and relative humidity probe
HMP155

General settings PMT16A

Barometric pressure sensor BARO-1

General settings QMT110_1

Soil/water temperature sensor QMT110

General settings QMT110_2

Soil/water temperature sensor QMT110

General settings RG13

Rain gauge RG13

General settings CMP6

(1

Global radiation sensor CMP6

General settings IRU_9429

Snow height sensor IRU-9429

General settings WIND

Wind sensor

General settings WA15

Wind sensor type
0 = Ultrasonic WMT700 series
1 = Mechanical WAV15/WAA15

(1

Global radiation sensor CMP6 has unique sensitivity factor that needs

to be entered to the AWS330 system as described in section Replacing
CMP6 on page 184.

Settings: 0 = Sensor/option is not selected, 1= Sensor/option is selected.