Installing snow depth sensor iru-9429 – Vaisala AWS330 User Manual

Page 87

Advertising
background image

Chapter 4 _______________________________________________________________ Installation

VAISALA _______________________________________________________________________ 85

Installing Snow Depth Sensor IRU-9429

Snow Depth Sensor IRU-9429 is installed on the sensor support.

1.

Attach the installation plate (number 5 in Figure 43 below) to the
sensor support.

2.

Place the sensor (4) through the installation plate and fasten with
the hose clamp (6). Use the screw that comes with the clamp and
tighten with wrench 10 mm.

3.

Attach the sensor cover (4) to its place using the screws (7).

4.

Bind the cable to sensor arm with cable ties.

5.

Connect the sensor cable to the SNOW DEPTH connector on the
bottom of the enclosure; see section Connecting Sensor Cables on
page 95.

1012-185

Figure 43

Snow Depth Sensor IRU-9429 Installation

The following numbers refer to Figure 43 above:
1 = Pole

mast

2 = Sensor

arm

3 = Cover

IRUFIXSET

4 = Sensor

IRU-9429

5 = Installation plate IRUFIXSET
6 = Hose clamp; use wrench 10 mm
7 = Screw M6x10 DIN912 A4, 2 pcs; use Allen key 5 mm
8 = Spring washer B6 DIN127 A4, 2 pcs
9 = Screw M6x16 DIN912 A4; use Allen key 5 mm

Advertising