Determining sensor status – Vaisala AWS330 User Manual

Page 215

Advertising
background image

Chapter 7 ___________________________________________________________ Troubleshooting

VAISALA ______________________________________________________________________ 213

Determining Sensor Status

Sensor status values give indication about the general status of the sensor
interfaces. You have two alternatives to view the status value for a
sensor:

1.

Status for all sensors is displayed in the Table message; see section
Table on page 28. Table message can be polled into view by typing
TABLE into the AWS Client terminal window while connection is
established but QML logger is not in command mode. If QML
logger is in command mode, type CLOSE first.

2.

For conventional sensors, open the Calibration window from the
Settings menu in the AWS Client software; see Figure 123 below.
The sensor list is displayed on the left side of the window. The
Status field shows the status of the selected sensor. To read the
latest sensor status and measurement values, click the Refresh
button. Table 58 on page 214 describes the other fields in the
Calibration window.

1012-208

Figure 123 Settings Menu: Calibration Window