Changing Pressure Sensor BARO-1

CAUTION

Use an antistatic wrist strap to protect yourself and the equipment from
ESD (electrostatic discharge).

If the BARO-1 pressure sensor needs to be replaced, do the following:

1.

Remove the QML201C logger cover.

2.

Unscrew the four mounting screws (number 1 in Figure 107 below)
holding BARO-1.

3.

Unplug the pressure hose (2) that connects BARO-1 to the logger
body.

4.

Remove the BARO-1 pressure sensor from the logger.

5.

Install a new pressure sensor in the reverse order.

6.

Pack the old sensor in the padded antistatic package that the
replacement sensor came in.

1010-096

Figure 107 Changing BARO-1 Pressure Sensor

The following numbers refer to Figure 107 above:
1 = Mounting

screws

2 = Pressure

hose