Table – Vaisala AWS330 User Manual

Page 30

Advertising
background image

User's Guide ______________________________________________________________________

28 __________________________________________________________________ M211296EN-B

Table

Table message is a message in readable format with instant values and
sensor status values.

The following values are displayed in the table message:

Table 13

Table Message Values

Row Label/Column

Instant

Average

Status

(1

Station name

Station name

Date

Date time UTC

Internal temperature [°C] Logger internal

temperature

DC supply voltage [V]

Logger DC supply
voltage

Temperature [°C]

HMP155 air
temperature

1 min average
temperature

HMP155 air
temperature status

Relative humidity [%]

HMP155 relative
humidity

1 min average
relative
humidity

HMP155 relative
humidity status

Wind direction [deg]

3 sec average
wind direction

10 min average
wind direction

WMT700 status
Not available for
WAV15 (99)

Wind speed [m/s]

3 sec average
wind direction

10 min average
wind speed

WMT700 status
Not available for
WAA15 (99)

Precipitation [mm],[mm/h] 1 min cumulative

precipitation from
rain gauge

Precipitation
intensity
calculated over
10 minutes

Rain gauge status

Snow depth [mm],[cm]

Sensor IRU 9429
reading

Snow height

IRU 9429 status

Soil temperature 1 [°C]

QMT102 soil
temperature

1 min average
soil
temperature

QMT102 status

Soil temperature 2 [°C]

QMT102 soil
temperature

1 min average
soil
temperature

QMT102 status

(1

See Appendix D, Sensor Status Values, on page 293.

Missing observation values are replaced with one or more slash '/'
characters.

See example Table Message on page 290.

Advertising