e) Totalizer #2 Power On Delay (Numerical entry)

Sometimes it is convenient to start the Totalizer only after a specified
power-up delay interval. Most of the mass flow meters and controllers
require some warm-up time from the power-up event in order to stabilize
process variable output and to get accurate reading. “Totalizer #2 Power
On Delay” option allows setting a specified time interval which must
elapse from the device power-up event before the Totalizer will be
activated. Valid settings are in the range of 0 to 3600 seconds (default
value is 0, no delay).

f) Totalizer #2 Auto Reload (Tabular entry)

This option allows automatic reset/reload Totalizer #2 when it reaches
preset Action Volume value (when configured to count UP) or zero value
(when configured to count Down). This feature may be convenient for
batch processing when predefined volume of the fluid must be
repeatedly dispensed into the process. The following selections are
available: Enabled or Disabled. The default entry is Disabled. Totalizer #2
Auto Reload selections can be set with the UP and DN buttons and are
accepted by pressing the ENT button.

g) Totalizer #2 Auto Reset Delay (Numerical entry)

This option may be desirable when “Totalizer #2 Auto Reload” feature is
enabled. Valid settings are in the range of 0 to 3600 seconds (default
value is 0, no delay).

h) Reset Totalizer #2 (Numerical entry)

Totalizers #2 reading can be reset by selecting “Reset Totalizer #2” menu
option. A typical display with Totalizer #2 Reset screen is shown below.

Once the “YES” option is selected, Totalizer #2 will be reset and the
following conformation screen will appear.

Reset Totalizer #2:

NO

YES

DO YOU WANT

RESET TOTALIZER?

*******************

Totalizer Has

been reset!

Press any Key...