Aalborg TIO Totalizer I/O Flow Monitor/Controller User Manual

Page 76

Advertising
background image

73

INDEX

NAME

DATA TYPE

NOTES

71

Total1_Volume_BkUp

float

Totalizer#1 backup volume in %s (saved every 6
minutes)

72

Total1_AutoReset

uint

Reset Total. Volume value when Totalizer value
equals Limit volume 0 - No, 1 - Yes

73

Total1_AtoResetDelay

uint

Delay in seconds before AutoReset will reset
Totalizer#1 volume reading to zero [0-3600]

74

Total1_Reserved

uint

Totalizer#1 reserved

75

Total2_Mode

uint

Totalizer#2 mode: (0-Disabled, 1-Enabled)

76

Total2_Config

uint

Totalizer#2 configuration (0-Count Up, 1-Count Down)

77

Total2_FlowStart

float

Start tot. at flow [0-1.0 fraction notation %F.S.]

78

Total2_VolStop

float

Limit volume in %s, 0 = disable

79

Total2_PowOnDelay

uint

Totalizer#2 power on delay in second [0-3600]

80

Total2_Volume_BkUp

float

Totalizer#2 backup volume in %s (saved every 6
minutes)

81

Total2_ReloadVolStop

uint

Reload VolStop value when Totalizer reading counts
down to zero 0 - No, 1 - Yes

82

Total2_ReloadDelay

uint

Delay in seconds before Reload VolStop value when
Totalizer reading counts down to zero [0-3600]

83

Total2_10SecBackUp

uint

Enable or Disable every 10 seconds EEPROM backup
(reserved for future version release)

84

Total2_Reserved

uint

Totalizer#2 reserved

85

Flow_Pulse_Mode

uint

Flow Pulse Output Mode (0=Dis'd, 1=En'd)

86

PulseFlowStart

float

Start pulse output at flow [0-1.0 fraction notation %F.S.]

87

Units_Per_Pulse

float

Units per pulse scaling

88

Active_Low_Time

uint

Number of ms output will be activated when pulse is
developed

89

Flow_Pulse_Reserved

uint

Pulse Output Reserved

90

FlowCondMode

uint

0 - No conditioning, 1 - NRF, 2 - Running Average

91

Flow_NRF_NSample

uint

Flow NRF Number of Samples [1 - 32]

92

Flow_NRF_ErrLimit

float

Flow NRF Error Value [0.05 10.0] %F.S. (FN)

93

Flow_NRF_TimeLimit

uint

Flow NRF Time Interval [0-199], 0 - disabled

94

Flow_Damping

uint

Reading Damping 0-500 ms

95

Flow_Window

uint

Flow running average window [0-32] 0-disable

96

FlowLinearizer

uint

Flow Linearizer: On (1), Off (0)

97

Flow_SC_Reserved

uint

Flow Signal Conditioner reserved

98

FlowTbl[0].FlowPFSIn

float

Flow Linearizer Index 0 PFS In (must be 0.0)

99

FlowTbl[0]. FlowPFSOut

float

Flow Linearizer Index 0 PFS Out (must be 0.0)

100

FlowTbl[1]. FlowPFSIn

float

Flow Linearizer Index 1 PFS In [0.0 – 1.0]

101

FlowTbl[1]. FlowPFSOut

float

Flow Linearizer Index 1 PFS Out [0.0 – 1.0]

102

FlowTbl[2]. FlowPFSIn

float

Flow Linearizer Index 2 PFS In [0.0 – 1.0]

103

FlowTbl[2]. FlowPFSOut

float

Flow Linearizer Index 2 PFS Out [0.0 – 1.0]

104

FlowTbl[3]. FlowPFSIn

float

Flow Linearizer Index 3 PFS In [0.0 – 1.0]

Advertising