C. TEMPERATURE MODULE

(Digital Models only)

-TP

Temperature Module ordered with Monitor/controller.

TPO

Temperature Module ordered separately includes label

# LTEMP.

Requires; Separate three (3) wire 1000Ω RTD

temperature sensor.

NOTE: OEM models require an additional display harness, part

number TPMH. See OEM Installation.

1. DESCRIPTION

The Temperature Module (TPO) gives the Monitor/controller more

flexibility for the user by being in the same package.

The Temperature Module is driven by the main display output and

is very simple to install.

The Temperature Module and Temperature Sensor SYSTEM

utilize a unique 3 wire technique by which errors are greatly

reduced.

The Temperature Module has its own 0-5VDC output.

TPO kit comes with all items necessary to install and operate: TP

Module; front panel harness with switch, bezel, cap and two O-

rings (006 & 008); and TEMPERATURE label (# LTEMP).

An alarm/control function may be added to the TP by ordering the

THO harness kit.

Specifications

±200°C (±200°F Special Order Only)

Accuracy:

±0.2 w/ICE

±0.5 w/out ICE

Display Resolution = 0.1

Output:

0-5VDC

Connections - 2

Sensor Input:

Separate 1000Ω RTD temperature sensor.

Connections:

Three (3) wire for increased accuracy over long

distances).

Calibration

Zero and Full Scale, FS (0 & 5VDC): Factory Set Simple pots

Display (CAL): Full Scale, FS (199.9) Factory Set Simple pot

Operates on safe ±5VDC supplied by the Main CB.

2. INSTALLATION

Briefly -

The Temperature Module replaces the plastic display retainer

plate attached to the front panel.

The display harness plugs into the Temperature Module instead of

the display.

The sensor leads are connected to the Temperature Module. See

figure III.C.1.

The display switch is installed in the upper front panel as shown in

figure III.C.4.

A “TEMPERATURE” label is added to upper front panel next to the

Display Select switch as shown in figure III.C.4.

WARNING: BEFORE STARTING, IF MONITOR/

CONTROLLER IS INSTALLED, ENSURE THE POWER

IS OFF. FAILURE TO DO SO COULD CAUSE DAMAGE

TO THE INSTRUMENT, AND COULD BE HARMFUL OR

FATAL

TO

PERSONNEL.

ONLY

QUALIFIED

PERSONNEL

SHOULD

INSTALL

OR

SERVICE

ELECTRICAL EQUIPMENT.

Physical

If the front panel has all ready been removed from the enclosure

skip to 3.

1. Using a standard slot screwdriver remove the

screws on the front panel.

2. Carefully wiggle the front panel to loosen the gasket and

pull gently toward you. Do not pull more than

about 8 inches/20CM or you could damage the wiring

harness.

3. Turn the front panel around so that the back side is

facing you.

4. Using a standard slot screwdriver remove the four (4)

screws holding the plastic display retainer plate to the

front panel. When the screws have been removed, the

plastic display retainer plate and the display will be

free from the front panel.

27

Figure III.C.1

DISPLAY SWITCH

(UPPER FRONT PANEL)

TEMP

CONTRO

L

FS

ZERO

DIS

SP2

HYS2

DISPLAY CONNECTION

DISPLAY

SELECT

TEMP

SENSOR

0-5VDC

OUTPUT

(-)

(+)

BRN

BLU

+

-

0- 5VDC

SPC

TEMP

CONTROL

HARNESS

TEMPERATURE

SENSOR INPUT

Orange

Blue

Brown

RECONNECT

DISPLAY

HARNESS

HERE

DISPLAY IS ON THE

BACK SIDE OF THE

TEMPERATURE

MODULE

JUMPER

OR

INC

INC

DEC

DEC

TP/TPO - TEMPERATURE MODULE

BR BL

OR

-

+

DISPLAY

!

CAUTION - READ FOLLOWING CAREFULLY

Advertising
This manual is related to the following products: