Myron L 729II User Manual

Page 43

Advertising
background image

E.

DUAL TEMPERATURE MODULE &

4-20mA OUTPUT MODULE

(Digital and OEM Models ONLY)

-TP/TPO Temperature Module.

-4A/4AO 4-20mA Self/Remote-powered Isolated

output module.

1. DESCRIPTION

The following instructions describe how install BOTH the 4A/4AO

and the TP/TPO Modules to a Digital model Monitor/controller.

Specifications

See individual Data Sheets and installation instructions.

Requires Plastic Spacers P# SP4819.

2. INSTALLATION

Briefly -

The Temperature Module replaces the plastic display retainer

plate attached to the front panel as described in Temperature

Module Installation Instructions except threaded plastic spacers

are utilized in place of the screws.

The 4AO Module is STACKED on top of the TPO Module utilizing

above spacers as shown in figure III.E.1.

Setup and operation for both modules is the same as described in

their respective Data Sheet/Installation Instructions.

WARNING: BEFORE STARTING, IF MONITOR/

CONTROLLER IS INSTALLED, ENSURE THE POWER

IS OFF. FAILURE TO DO SO COULD CAUSE DAMAGE

TO THE INSTRUMENT, AND COULD BE HARMFUL OR

FATAL

TO

PERSONNEL.

ONLY

QUALIFIED

PERSONNEL

SHOULD

INSTALL

OR

SERVICE

ELECTRICAL EQUIPMENT.

This procedure assumes the front panel is removed, and the

TP/TPO has already been installed.

1. Install spacers as shown in figure III.E.1.

2. Attach 4AO Module five (5) wire harness, and signal

and power wires as required as described in 4AO

Data Sheet/Installation Instructions.

3. Carefully reinstall the front panel, bottom first.

Ensure no wires have been pinched between

enclosure and front panel.

4. Reinstall the screws and tighten.

5. To operate, turn power ON.

39

!

CAUTION - READ FOLLOWING CAREFULLY

FRONT PANEL

LEFT SIDE VIEW

PLASTIC

SPACERS (4)

TP/TPO

4A/4AO

SCREWS

Figure III.E.1