SkyTrak 6036 Service Manual User Manual

Page 327

Advertising
background image

Section 10.

Electrical System

10-65

Model 6036/6036T S/N 9B0500 thru 14833

Trouble

Probable Cause

Remedy

Reference

Switches and Solenoids—REVERSE SWITCH AND BACKUP ALARM

Backup alarm
doesn’t sound
with travel select
lever in REVERSE.

1. No voltage at backup

alarm; broken wire or
circuit breaker (11) doesn’t
reset.

2. Defective reverse switch.

Replace wiring and circuit
breaker as required.

Replace reverse switch.

See para. 10.4

See para. 10.7.5

Switches and Solenoids—STEERING SELECT SWITCH AND SOLENOID

Steering select
switch fails to
select mode or
selects incorrect
steering mode.

1. Short circuit or broken

wire.

2. Circuit breaker stuck in

open position.

3. Steering select switch is

defective.

4. Steering select solenoid is

defective.

Eliminate short or repair or
replace wire.

Replace circuit breaker.

Remove steering select
switch and check for
continuity in each position and
replace switch if defective.

Remove steering select
solenoid and test for correct
operation.

See para. 10.7.6

See para. 10.4

See para. 10.7.6

See para. 10.7.7

Gauges and Indicator Lights—HOURMETER

Hourmeter
Doesn’t
Operate.

1. Defective wiring and

ground.

2. Incorrect voltage at meter

terminals.

Renew wiring and correct
ground.

Required voltage is 9 to
36 Vdc.

See para. 10.8.3

See para. 10.8.3

Backup alarm
sounds with travel
select lever in
NEUTRAL AND
FORWARD

1. Short circuit in wiring.

2. Defective reverse switch.

Determine and repair cause of
short circuit.

Test and replace reverse
switch as required.

See para. 10.2.2

See para. 10.7.5

Hourmeter is
Inaccurate.

Check running indicator flag
wheel.

Replace hourmeter if
defective.

See para. 10.8.3

Advertising