Section 10.

Electrical System

10-74

Model 6036/6036T S/N 9B0500 thru 14833

Trouble

Probable Cause

Remedy

Reference

Cab Heater for Enclosed Cab—CAB HEATER SWITCH

Blower fan motor
doesn’t run.

See para. 10.4

See para. 10.12.1

See para. 10.12.2

See para. 10.12.2

1. Check circuit breaker/

fuses.

2. Check continuity through

blower switch in high and
low positions.

3. Check motor and fan for

mechanical binding.

4. Open heater ground at

mechanical support.

Replace circuit breaker if
open.

Replace switch if defective.

Realign motor and fan as
required to relieve binding.

Check ground at mechanical
support for presence of tooth-
type washer.

Cab Heater for Enclosed Cab—HEATER FAN MOTOR AND COIL

Blower fan motor
doesn’t run.

1. Check circuit breaker.

2. Check motor and fan for

mechanical binding.

3. Check continuity through

blower switch in high and
low positions.

4. Open heater ground at

mechanical support.

Replace circuit breaker if
open.

Realign motor and fan as
required to relieve binding.

Replace switch if defective.

Check ground at mechanical
support for presence of tooth-
type washer.

See para. 10.4

See para. 10.12.2

See para. 10.12.1

See para. 10.12.2