Vehicle speed – AEM 30-71XX Infinity Stand-Alone Programmable Engine Mangement System Full Manual User Manual

Page 190

Advertising
background image

184

© 2014 AEM Performance Electronics

Infinity User Manual

Digital input selector for Turbo Speed.

Turbo Speed Multiplier:

This is a multiplier which is used to synchronize the actual speed of the vehicle to the Infinity
Tuner's Vehicle Speed.
Min value = 0, Max value = 50

Vehicle Speed Input:
Select vehicle speed input from VSS_Digital, Ground Speed, or Drive Wheel Speed.

VSS Digital Input:
Select digital input method for Vehicle Speed sensor, default is Digital 4 (C1-25 on Infinity 8/10
and C1-29 on Infinity 6/8h).

Vehicle Speed Calibration:
This is a multiplier which is used to synchronize the actual speed of the vehicle to the Infinity
Tuner's Vehicle Speed.
Min value = 0, Max value = 10

Vehicle Speed Smoothing:
Value used to smooth signal.
Min value = 0%, Max value = 99.9%