4 channel wideband uego controller setup – AEM 30-71XX Infinity Stand-Alone Programmable Engine Mangement System Full Manual User Manual

Page 274

Advertising
background image

268

© 2014 AEM Performance Electronics

Infinity User Manual

4 Channel Wideband UEGO Controller Setup

Infinity Supports 4 channel UEGO CAN input for logging purposes. Modes must be properly set
up and if designated cylinders overlap, jittery values will be present in any overlapping cylinder
sensor. Description of different modes are as follows:

Mode 1: Cylinders 1, 2, 3, 4
Mode 2: Cylinders 5, 6, 7, 8
Mode 3: Cylinders 1, 3, 5, 7
Mode 4: Cylinders 2, 4, 6, 8
Mode 5: Cylinders 9, 10, 11, 12
Mode 6: Cylinders 1, 2, 3
Mode 7: Cylinders 4, 5, 6

*NOTE: Proper use of UEGO modes is vital for ensuring data is captured correctly. See 4ch
UEGO manual to configure modes or verify operating mode of controller.

A, B, and C relate to specific UEGO controllers
A refers to a controller in mode 1, 3, or 6
B refers to a controller in mode 2, 4, or 7
C refers to a controller in mode 5

UEGO Cyl 1-12:
Units: Lambda
Range: 0-6.5535
Displays current lambda value for each individual cylinder. If value is unstable, verify 4 channel
UEGO does not have overlapping channels.

UEGO EBP A, B, C:
Units: psig
Range: 0-655.35
Displays Exhaust Back Pressure captured from specified controller

Diagnostics:

UEGO Error:
Has information regarding individual cylinders such as: Ready, Heater Open Error, VM Error, UN
Error, IP Error, Heater Time-Out Error, Heater Short Error, and Overtemp Error.

UEGO EBP Status A, B, C:
Displays information about controller and EBP sensor such as low voltage for UEGO controller
and EBP sensor, sensor ready status, and if sensor is detected or not.

Advertising