Universal Pinout, Infinity-6/8h

Infinity Pin

Hardware Ref.

Hardware Specification

Notes

C1-1

LowsideSwitch_4_Out

Lowside switch, 1.7A max, NO internal
flyback diode.

12V pullup

See Setup Wizard Pages "User GPOs" for
activation criteria and "LowSide Assignment
Tables" for output assignment

C1-2

LowsideSwitch_5_Out

Lowside switch, 6A max with internal
flyback diode. Inductive load should
NOT have full time power.

12V pullup

See Setup Wizard Page "LowSide Assignment
Tables" for output assignment and 2D table
"LS5_Duty [%]" for activation.

C1-3*

LowsideSwitch_6_Out
(*Infinity-6 Only)

Lowside switch, 6A max with internal
flyback diode. Inductive load should
NOT have full time power.

No pullup

Available on P/N 30-7106 only. See Setup
Wizard Page "LowSide Assignment Tables" for
output assignment and 2D table "LS6_Duty [%]"
for activation.

C1-3**

Injector 7_Out
(**Infinity-8H Only)

For use with high impedance (10-15
ohms) injectors only, 1.7A max.

Available on P/N 30-7108 only

C1-4*

LowsideSwitch_7_Out
(*Infinity-6 Only)

Lowside switch, 6A max, NO internal
flyback diode.

No pullup

Available on P/N 30-7106 only. See Setup
Wizard Page "LowSide Assignment Tables" for
output assignment and 2D table "LS7_Duty [%]"
for activation.

C1-4**

Injector 8_Out
(**Infinity-8H Only)

For use with high impedance (10-15
ohms) injectors only, 1.7A max.

Available on P/N 30-7108 only

C1-5

UEGO 1 Heat_Out

Bosch UEGO controller

Lowside switch for UEGO heater control.
Connect to pin 4 of Bosch UEGO sensor. NOTE
that pin 3 of the Sensor is heater (+) and must be
power by a fused/switched 12V supply.

C1-6

UEGO 1 IA_In

Trim Current signal. Connect to pin 2 of Bosch
UEGO sensor

C1-7

UEGO 1 IP_In

Pumping Current signal. Connect to pin 6 of
Bosch UEGO sensor

C1-8

UEGO 1 UN_In

Nernst Voltage signal. Connect to pin 1 of Bosch
UEGO sensor

C1-9

UEGO 1 VM_In

Virtual Ground signal. Connect to pin 5 of Bosch
UEGO sensor.

C1-10

+12V_R8C_CPU_In

Dedicated power management CPU

Full time battery power. MUST be powered
before the ignition switch input is triggered (See
C1-48).

C1-11

Coil 4_Out

25 mA max source current

0-5V Falling edge fire. DO NOT connect directly
to coil primary. Must use an ignitor OR CDI that
accepts a FALLING edge fire signal.

C1-12

Coil 3_Out

25 mA max source current

0-5V Falling edge fire. DO NOT connect directly
to coil primary. Must use an ignitor OR CDI that
accepts a FALLING edge fire signal.

C1-13

Coil 2_Out

25 mA max source current

0-5V Falling edge fire. DO NOT connect directly
to coil primary. Must use an ignitor OR CDI that
accepts a FALLING edge fire signal.

C1-14

Coil 1_Out

25 mA max source current

0-5V Falling edge fire. DO NOT connect directly
to coil primary. Must use an ignitor OR CDI that
accepts a FALLING edge fire signal.