DBW Custom Setup and Troubleshooting

Drive by wire is disabled by default until Drive By Wire Wizard is completed.

Additional PID controls can be found in

Wizard Setup -> DBW Tuning

DBW_ThrottleCurve1:
Units: Engine Speed [RPM] vs DBW_APP1[%]Filtered vs Throttle %
Range: Min value = 0, Max value = 127.5
Map used for controlling throttle % based off analog APP1 input (C2-13 Analog 18 in Infinity
8/10/12)

DBW_ThrottleCurve2:
Units: Engine Speed [RPM] vs DBW_APP1[%]Filtered vs Throttle %
Range: Min value = 0, Max value = 127.5
Map used for controlling throttle % based off analog APP1 input (C2-13 Analog 18 in Infinity
8/10/12)

Note: Details on switching between throttle curves can be found at

Advanced Tuning -> Multi-

Map Features

<placeholder for 1D tables like DBW1_TPS_AB_Rel>

Tuning Tips and Troubleshooting:

Recommend that the initial DBW setup and tuning be done with the engine off and a battery
charger connected in order to bring Battery Volts up to the normal voltage you might find when
the engine is running, for instance something greater than 13V.

A 'DBW' tab is available. It contains useful data and plot windows to assist in tuning the DBW
PIDs.