Universal pinout, infinity-8/10/12 – AEM 30-71XX Infinity Stand-Alone Programmable Engine Mangement System Full Manual User Manual

Page 358

Advertising
background image

352

© 2014 AEM Performance Electronics

Infinity User Manual

Universal Pinout, Infinity-8/10/12

Infinity Pin

Hrdwr Ref.

Hardware Specification

Notes

C1-1

LowsideSwitch_4_Out

Lowside switch, 4A max, NO internal
flyback diode.

No pullup

Normally used as A/C Relay Control output.

C1-2

LowsideSwitch_5_Out

Lowside switch, 4A max with
internal flyback diode. Inductive
load should NOT have full time
power.

No pullup

See Setup Wizard Page "LowSide Assignment
Tables" for output assignment and 2D table
"LS5_Duty [%]" for activation.

C1-3

LowsideSwitch_6_Out

Lowside switch, 4A max with
internal flyback diode. Inductive
load should NOT have full time
power.

No pullup

See Setup Wizard Page "LowSide Assignment
Tables" for output assignment and 2D table
"LS6_Duty [%]" for activation.

C1-4

UEGO 1 Heat_Out

Bosch UEGO controller

Lowside switch for UEGO heater control. Connect
to pin 4 of Bosch UEGO sensor. NOTE that pin 3 of
the Sensor is heater (+) and must be power by a
fused/switched 12V supply.

C1-5

UEGO 1 IA_In

Trim Current signal. Connect to pin 2 of Bosch UEGO
sensor

C1-6

UEGO 1 IP_In

Pumping Current signal. Connect to pin 6 of Bosch
UEGO sensor

C1-7

UEGO 1 UN_In

Nernst Voltage signal. Connect to pin 1 of Bosch
UEGO sensor

C1-8

UEGO 1 VM_In

Virtual Ground signal. Connect to pin 5 of Bosch
UEGO sensor.

C1-9

Flash_Enable_In

10K pulldown

Not usually needed for automatic firmware
updates through Infinity Tuner. If connection errors
occur during update, connect 12 volts to this pin
before proceeding with upgrade. Disconnect the
12 volts signal after the update.

C1-10

+12V_R8C_CPU_In

Dedicated power management CPU

Full time battery power. MUST be powered before
the ignition switch input is triggered (See C1-65).

C1-11

Coil 4_Out

25 mA max source current

0-5V Falling edge fire. DO NOT connect directly to
coil primary. Must use an ignitor OR CDI that
accepts a FALLING edge fire signal.

C1-12

Coil 3_Out

25 mA max source current

0-5V Falling edge fire. DO NOT connect directly to
coil primary. Must use an ignitor OR CDI that
accepts a FALLING edge fire signal.