Tuning Guide

187

© 2014 AEM Performance Electronics

Oil Temp Fail Min:
This Oil Temp Fail Min should be set to a value that is just above the oil temperature value when
the sensor is unplugged.
Oil Temp Fail Max must be > Oil Temp Fail Min.
User entries that do not meet this criteria are not allowed.
Min value = -50, Max value = 300

Oil Temp Fail Max:
This Oil Temp Fail Max should be set to a value that is just below the air temperature value when
the sensor is shorted. This will trigger the failsafe feature. This can be tested and entered by
carefully inserting each leg of a paper clip into each terminal of the wiring harness.
Oil Temp Fail Max must be > Oil Temp Fail Min.
User entries that do not meet this criteria are not allowed.
Min value = -50, Max value = 300

Oil Temp Failsafe On:
When clicking, the failsafe feature is enabled. This is typically used when the sensor is
mistakenly unplugged or has failed.

Oil Temp Failsafe:
The value entered here will be displayed and used for the air temperature corrections when the
sensor has failed or is simply unplugged. Min value = -50, Max value = 300

Oil Temp Smoothing:
Value used to smooth signal. Min value = 0, Max value = 98

Multi-map features that include blending tables can be configured in this section.