Elkhart Brass Unibody Valve User Manual
Page 17
17
800.346.0250 • www.elkhartbrass.com
3. Hold the actuator assembly above valve body assembly and align the actuator shaft with
the slot in the ball as shown in Figure 12 for desired gear position on valve body as shown
in Figure 13.
Figure 12
4. Push the actuator assembly down against valve body assembly and rotate the actuator
assembly in both directions slightly while pushing assembly against valve body until
actuator drops into slot in valve ball as shown in Figure 12. There should be no gap
between the actuator assembly and the valve body as shown below.
5. The actuator assembly should be rotated on the valve body until the #10-24 socket head
cap screws line up with the tapped holes on the valve body. The actuator assembly may
be positioned in rotational increments of 45° on the valve body. Replace the 1/2" bolt
and washer that were removed in Step 2. Secure with a thread locker (Blue Loctite #242)
and tighten to 5-7 Ft-Lb.
6. It is recommended to apply a thread locker (Blue Loctite #242) to the screws fastening
the actuator to the valve. Fasten the actuator assembly to valve body assembly by
tightening the #10-24 socket head cap screws in an X pattern to a torque of 5 ft-lb.
Figure 13
Figure 14
No gap between
actuator assembly
and valve body
Ball in closed
position
Actuator shaft and
slot in ball align
Ball in closed
position