Elkhart Brass Unibody Valve User Manual

Page 17

Advertising
background image

17

800.346.0250 • www.elkhartbrass.com

3. Hold the actuator assembly above valve body assembly and align the actuator shaft with

the slot in the ball as shown in Figure 12 for desired gear position on valve body as shown

in Figure 13.

Figure 12

4. Push the actuator assembly down against valve body assembly and rotate the actuator

assembly in both directions slightly while pushing assembly against valve body until

actuator drops into slot in valve ball as shown in Figure 12. There should be no gap

between the actuator assembly and the valve body as shown below.

5. The actuator assembly should be rotated on the valve body until the #10-24 socket head

cap screws line up with the tapped holes on the valve body. The actuator assembly may

be positioned in rotational increments of 45° on the valve body. Replace the 1/2" bolt

and washer that were removed in Step 2. Secure with a thread locker (Blue Loctite #242)

and tighten to 5-7 Ft-Lb.

6. It is recommended to apply a thread locker (Blue Loctite #242) to the screws fastening

the actuator to the valve. Fasten the actuator assembly to valve body assembly by

tightening the #10-24 socket head cap screws in an X pattern to a torque of 5 ft-lb.

Figure 13

Figure 14

No gap between

actuator assembly

and valve body

Ball in closed

position

Actuator shaft and

slot in ball align

Ball in closed

position