IX. INSTALLATION

The valve control and display module, flow sensor and pressure sensor are compatible for use with 1 to

5 inch piping.

Note: Plumbing systems are always unique and may cause small deviations in the factory

calibration. It is recommended that the calibration procedure be performed after installation.

1. Install Control and Display Module (UBEC1, UBEC2, UBEC3, UICS2)

The control and display modules are interchangeable. It is recommended that the calibration be checked if

modules are swapped.

Note: it is recommended to have the control and display module mounted close to the associated

discharge valve.

1. Measure and mark mounting location for control module panel cutout and mounting screw holes. Make

sure there is clearance behind the panel for the display and cables before cutting holes. Refer to Figure

42 for layout and dimensions

.

2. Cut out a

3

/

4

inch diameter hole and drill four holes (clearance or tapped) for 10-32 mounting screws.

3. Place control module in position and secure with four screws.

4. Connect the cables and wires. Refer to Wiring section on Page 68.

Panel Cutout

Figure 42. Control Module Mounting Dimensions

Mounting holes are clearance or

tapped for 10-32 screws.

4¼"

4¼"

2½"

3¾"

3½"

3½"

3¾"

Diameter

Advertising