VII. INTRODUCTION: ELECTRIC VALVES

1. Electric Controller Overview (UBEC1, UBEC2, UBEC3, UICS2)
Designed with precision in mind, the electric valve controller and integrated electronic display is easy to

operate. Monitor the valve position on a 10 LED valve position indicator. All controls and indicators are

located on the front of the control and display module. Controls are simple push buttons.
UBEC1 – Valve control with valve position indicator.

UBEC2 – Valve control with valve position indicator and digital pressure display.

UBEC3 – Valve control with valve position indicator, digital pressure display, and digital flowmeter.

UICS2 – Valve control with valve position indicator, digital pressure display, and CAF control with on/off

input as well as selectable preset positions for wet, medium, and dry CAF.

Electric Actuator Overview (E3F, E4F)
The E3F and E4F Unibody electric actuators have been designed to further simplify the use of electric valves

on a fire fighting apparatus. The control logic has been relocated to the top of the valve. This increases the sim-

plicity of wiring the valve as well as broadening the options for controlling the valve. The E3F and E4F

electric actuator utilize the J1939 data bus for control communication. All electronic components have been

potted with a two part epoxy to ensure a water tight seal.
2. Features
Programmable Preset

Automatic Adjusting of LED Displays for Day/Night Viewing

Datalink Interface for Primary/Remote Operation

Multiple Flow Rate Calibration Points (UBEC3)
Additional Information
For the latest design and application information on the Unibody Valve, Valve Controllers and Harnesses,

go to www.unibodyvalve.com
3. Specifications
Control and Display Module

Supply Voltage

12 or 24 VDC

Current:

Valve control circuit will handle a current load of 10 amps for valve sizes of 1.5, 2, 2.5, 3, 3.5, 4, 5, 6 and

8 inches.

Controller Dimensions:

Height 4¼"

Width 4¼"

Depth 2½"

Datalink Interface: CAN – bus
Flow Sensor

Type

Paddlewheel with Brass Housing for Saddle Clamp

Sensor Material

Acetal (Delrin) with Stainless Steel (316) Shaft

Excitation Voltage 5 VDC

Model Number

See Engineering Guide for available mounting styles

Pressure Sensor

Pressure Range

0 – 600 PSI

Proof Pressure

200 PSI

Excitation Voltage 5 VDC

Output Voltage

0.5 – - 4.75 VDC (Refer to Table 4)

Model Number

65106000

PRESSURE (PSI)

VOLTAGE (VDC)

0

0.5

100

1.21

150

1.56

200

1.92

250

2.27

300

2.625

600

4.75

Table 4. Pressure Sensor Output Voltage