60

ELKHART BRASS MANUFACTURING COMPANY, INC

Program ID Number (Code 2130)

This code sets the ID of the control and display module. A remote has to have the same ID as the primary.
1. Press and hold the OPEN and CLOSE buttons for 5 seconds.

Result: The PRESSURE display shows ENTER/CODE.

2. Enter code 2130

– Press OPEN button 2 times to enter 2

– Press CLOSE button to move the cursor to the next digit

– Press OPEN button 1 time to enter 1

– Press CLOSE button to move the cursor to the next digit

– Press OPEN button 3 times to enter 3.

Result: The PRESSURE display will show 2130.

3. After 3 seconds the current ID number shows in the display.
4. Change the ID numbers as desired.

– Use the CLOSE button to select the digit to change. The digit flashes.

– Use the OPEN button to change the value of the flashing digit.

5. Press the CAF SELECT button and hold for 5 seconds to exit and save the programmed parameters.

Program Pressure Display Unit of Measure (Code 2140)

There are three units of measure available for the pressure display: PSI=PSI; PCAL=kPa; bAr=BAR.
1. Press and hold the OPEN and CLOSE buttons for five seconds.

Result: The PRESSURE display shows ENTER/CODE.

2. Enter code 2140

– Press OPEN button 2 times to enter 2

– Press CLOSE button to move the cursor to the next digit

– Press OPEN button 1 time to enter 1

– Press CLOSE button to move the cursor to the next digit

– Press OPEN button 4 times to enter 4.

Result: The PRESSURE display shows 2140.

3. After 3 seconds the current unit of measure shows in the display.
4. Use the OPEN button to toggle between each unit of measure.
5. Press the CAF SELECT button and hold for 5 seconds to exit and save the programmed parameters.

Program Valve Polarity (Code 2160)

The control can be set for TYPE1 standard or TYPE2. TYPE1 valves have standard counter-clockwise to open

valve rotation. TYPE2 valves have clockwise to open valve rotation as required with EBXJ butterfly valves.
1. Press and hold the OPEN and CLOSE buttons for 5 seconds.

Result: The PRESSURE display shows ENTER/CODE.

2. Enter code 2160

– Press OPEN button 2 times to enter 2

– Press CLOSE button to move the cursor to the next digit

– Press OPEN button 1 time to enter 1

– Press CLOSE button to move the cursor to the next digit

– Press OPEN button 6 times to enter 6.

Result: The PRESSURE display shows 2160.

3. After 3 seconds TYPE1 (standard) or TYPE2 (reverse) shows in the display.
4. Use the OPEN button to toggle between the two.
5. Press the CAF SELECT button and hold for 5 seconds to exit and save the programmed parameters.