Air valve delay (code 2170) – Elkhart Brass Unibody Valve User Manual
Page 61
61
800.346.0250 • www.elkhartbrass.com
Air Valve Delay (Code 2170)
Factory programmed value: 1 Seconds
Options:
0 to 999
This code sets the time delay between pressing the CAF ON button to set the valve position and when
the air solenoid valve is activated.
1. Press and hold the OPEN and CLOSE buttons for 5 seconds.
Result: The PRESSURE display shows ENTER/CODE.
2. Enter code 2170.
– Press OPEN button 2 times to enter 2
– Press CLOSE button to move the cursor to the next digit
– Press OPEN button 1 time to enter 1
– Press CLOSE button to move the cursor to the next digit
– Press OPEN button 7 times to enter 7.
Result: The PRESSURE display will show 2170.
3. After 3 seconds the PRESSURE display shows AVDELAY.
4. Press OPEN button.
Result: The PRESSURE display shows the programmed air valve time delay.
5. Adjust the time delay as desired.
– Use the CLOSE button to select the digit to change. The digit flashes.
– Use the OPEN button to change the value of the flashing digit.
6. Press the CAF SELECT button and hold for 5 seconds to exit and save the programmed parameters.