ElmoMC AC Input Digital Servo Drives-Bassoon Cable Kit User Manual

Page 22

Advertising
background image

Cornet Installation Guide

Installation

MAN-CORIG (Ver. 1.502)

www.elmomc.com

22

jjj.

Ensure that in normal operating conditions, the shielded wires and drain carry no

current. The only time these conductors carry current is under abnormal conditions,
when electrical equipment has become a potential shock or fire hazard while
conducting external EMI interferences directly to ground, in order to prevent them
from affecting the drive. Failing to meet this requirement can result in
drive/controller/host failure.

kkk.

After completing the wiring, carefully inspect all wires to ensure tightness, good solder

joints and general safety.

The Cornet has the following connectors:

Type

Function

Port on Cornet

Connector Location

8-Pin RJ-45

RS-232

COMM. 1

AC3

AC2

AC1

PE

M3

M2

M1

FEEDBACK B

FEEDBACK A

ANALOG INPUTS

COMMITTED I/O

COMM.2

GENERAL I/O

COMM.1

COR0018A

PE

9-Pin D-Sub socket

Analog Input

ANALOG INPUTS

8-Pin RJ-45, RJ-45

CAN … CAN

(CAN)

COMM. 2

15-Pin high-density D-

Sub plug

Digital Inputs

COMMITTED I/O

15-Pin high-density D-

Sub socket

Digital Outputs

GENERAL I/O

15-Pin D-Sub socket

Main feedback

FEEDBACK A

15-Pin D-Sub plug

Auxiliary Feedback

FEEDBACK B

2-Pin terminal strip

Molex

Auxiliary power

supply

+,

8-Pin terminal block

Molex

Mains and motor

power

M1, M2, M3, PE,

PE, AC1, AC2, AC3

Table 1: Connectors on the Cornet