ElmoMC AC Input Digital Servo Drives-Bassoon Cable Kit User Manual

Page 67

Advertising
background image

Cornet Installation Guide

Technical Specifications

MAN-CORIG (Ver. 1.502)

www.elmomc.com

67

1.23.1. Digital Input Interfaces (on the COMMITTED I/O port)

Feature

Details

Connector Location

Type of input

Optically isolated
Single ended
PLC level

FEEDBACK B

FEEDBACK A

ANALOG INPUTS

COMMITTED I/O

COMM.2

GENERAL I/O

COMM.1

COR0001A

Input current

=

2500

5

.

6 V

Vin

Iin

* Iin = 2.2 mA @ Vin = 12 V

Input current for

high speed

inputs

=

1250

5

.

6 V

Vin

Iin

* Iin = 4.4 mA @ Vin = 12 V

High-level input

voltage

12 V < Vin < 30 V, 24 V typical

Low-level input

voltage

0 V < Vin < 6.5 V

Minimum pulse

width

> 4 x TS, where TS is sampling time

Execution time

(all inputs):

the time from

application of

voltage on input

until execution

is complete

If input is set to one of the built-in functions —

Home, Inhibit, Hard Stop, Soft Stop, Hard and Soft

Stop, Forward Limit, Reverse Limit or Begin —

execution is immediate upon detection: 0 < T < 4 x

TS
If input is set to General input, execution depends
on program. Typical execution time: ≅ 0.5 msec.

D

IG

IN

PU

T

2.5

K

R

ele

va

nt

In

pu

t R

etu

rn

Digital Input Schematic

High-speed

inputs -

minimum pulse

width, in high-

speed mode

T < 5 µsec

Notes:

Home mode is high-speed mode and can be used
for fast capture and precise homing.
High speed input has a digital filter set to same
value as digital filter (EF) of main encoder.
Highest speed is achieved when turning on
optocouplers.