2 virtual master/real master, 9400 technology applications | electronic gearbox – Lenze E94AxHE Technology Application Electronic gearbox User Manual

Page 11

Advertising
background image

EDS94TA10030xxxx EN 1.2 - 11/2009

L

11

9400 Technology applications | Electronic gearbox

Introduction

Virtual master/real master

3.2

Virtual master/real master

Virtual master

[3-1]

Example "Virtual master" (with master value transmission via digital frequency extension module)

Real master

[3-2]

Example "Real master" (with master value transmission via digital frequency extension module)

In an interconnection, a drive takes

over the task of the (virtual) master

and is the first slave drive at the same

time.

The master value created in the TA by

the "Virtual master" function is

transmitted via a bus system or the

digital frequency output to the other

slave drives.

d

v

R

i

v

Virtual master /

Slave 1

X10: DFout

The master value for a slave drive can

be also specified by a real master (e.g.

external encoder).

The master value can be specified e.g.

via the digital frequency input of the

master frequency extension module or

a bus system.

The master value (possibly conditioned

in the TA) by the "Virtual master"

function is transmitted via a bus

system or the digital frequency output

to the other slave drives.

d

v

d

v

R1

R2

1

2

i

1

i

2

v

1

v

2

X10: DFout

Real master/

Slave 1

X9: DFin