2 master value source: digital frequency input, 3 master value source: bus system, 9400 technology applications | electronic gearbox – Lenze E94AxHE Technology Application Electronic gearbox User Manual

Page 43

Advertising
background image

EDS94TA10030xxxx EN 1.2 - 11/2009

L

43

9400 Technology applications | Electronic gearbox

Parameter setting & configuration

Selection of master value source and output

5.3.2

Master value source: Digital frequency input

To use the digital frequency input as master value source, the controller must be provided

with digital frequency extension module (E94AYFLF).
To ensure the integration of the extension module in the application, the TA "Electronic

gearbox" must be used as technology application.

5.3.3

Master value source: Bus system

When the master value is selected via a bus system as e.g. system bus (CAN) it is possible

to first extrapolate the received position information to compensate higher bus

transmission cycles.

Parameter setting: Tab Application parameters  dialog level Overview Electronic

gearbox Master value extrapolation

Configuration: Tab FB editor  FB

MotionBusIn

Note!

The technology application "Electronic gearbox" MotionBus" which can also be

selected in the application catalog does not contain any interfaces to the digital

frequency extension module.

Parameter

Lenze setting

Value Unit

C03550

Number of extrapolation cycles

1

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

TRUE  Activate extrapolation

C03058/9