9400 technology applications | electronic gearbox – Lenze E94AxHE Technology Application Electronic gearbox User Manual

Page 40

Advertising
background image

9400 Technology applications | Electronic gearbox

Parameter setting & configuration

Machine parameters

40

L

EDS94TA10030xxxx EN 1.2 - 11/2009

Example of determining the machine parameters for the slave axis

Tip!
The feed constant corresponds to the movement on the machine side when the

gearbox output shaft carries out one revolution (for selection as angle = 360°).
When the unit is set, the real unit of the machine for the selection of physical

values (e. g. speeds, accelerations and decelerations) is defined.

1. Set gearbox ratio for the motor in the form of a quotient

(numerator and denominator): i

2

= 12.612 = 12612/

1000
– Numerator (C02520) = 12612
– Denominator (C02521) = 1000

2. Set the same gearbox ratio for the position encoder:

– Numerator (C02522) = 12612
– Denominator (C02523) = 1000

3. Set feed constant (C02524).

– For the conveyor drive: Vk = d

2

* π = 628,3185 mm

4. Set the selection "mm" as unit (C02525).

d

2

i

2

= 200 mm

= 12.612

Advertising