2 clutchelectricalshaft, 9400 technology applications | electronic gearbox – Lenze E94AxHE Technology Application Electronic gearbox User Manual

Page 69

Advertising
background image

EDS94TA10030xxxx EN 1.2 - 11/2009

L

69

9400 Technology applications | Electronic gearbox

Parameter setting & configuration

Parameterisable function blocks

5.16.2

ClutchElectricalShaft

Is an instance of

Function

L_LdClutchV



Virtual clutch ( 46)

Parameter

Possible settings

Information

C03665/1

0.010

s

130.000 Clutch in ramp

• Acceleration ramp for

synchronising to dnSpeedIn_s.

• Initialisation: 1.000 s

C03665/2

0.010

s

130.000 Decoupling ramp

• Deceleration ramp for

synchronising to dnSetSpeed_s.

• Initialisation: 1.000 s

C03665/3

0.010

s

130.000 Ramp for positive opening operation

• Deceleration ramp for positive

opening operation.

• Initialisation: 1.000 s

C03666

Character string

Speed unit

• Read only

C03667

-214748.3647

unit/t

214748.3647 Reference speed

• Read only

• Reference value for selecting

speeds.

C03668

0.010

s

130.000 S-ramp time

• For limiting the jerk

• Initialisation: 1.000 s

C03670

-2147483647

2147483647 State

• Display of the bit-coded output

signal dnState.

C03672

-214748.3647

unit

214748.3647 Setpoint speed after decoupling

• Read only

• Is generated from the speed

signal dnSetSpeed_s.

C03673

-214748.3647

unit

214748.3647 Speed at the input

• Read only

• Is generated from the speed

signal dnSpeedIn_s.

C03674

-214748.3647

unit

214748.3647 Speed at the output

• Read only

• Is generated from the speed

signal dnSpeedOut_s.