12 virtualmaster, 9400 technology applications | electronic gearbox – Lenze E94AxHE Technology Application Electronic gearbox User Manual

Page 78

Advertising
background image

9400 Technology applications | Electronic gearbox

Parameter setting & configuration

Parameterisable function blocks

78

L

EDS94TA10030xxxx EN 1.2 - 11/2009

5.16.12

VirtualMaster

Is an instance of

Function

L_LdVirtualMaster

"Virtual master"



Master value source: Virtual master ( 42)

Parameter

Possible settings

Information

C03565

Virtual master operating mode

0 Continuous operation

Lenze setting

1 Inching
2 Handwheel function

C03566

Character string

Speed unit

• Read only

C03567

-214748.3647

unit/t

214748.3647 Reference speed

• Read only

• Reference value for selecting

speeds.

C03568/1

-214000.0000

unit/t

214000.0000 Master speed 1

• Initialisation: 1.0000 units/t

C03568/2

-214000.0000

unit/t

214000.0000 Master speed 2

• Initialisation: 1.0000 units/t

C03569/1

0.0000

unit/t

214000.0000 Manual speed CW rotation

• Initialisation: 1.0000 units/t

C03569/2

0.0000

unit/t

214000.0000 Manual speed CCW rotation

• Initialisation: 1.0000 units/t

C03570/1

0.010

s

130.000 Ramp for manual jog

• Initialisation: 1.000 s

C03570/2

0.010

s

130.000 Ramp for continuous operation/

single cycle

• Initialisation: 1.000 s

C03570/3

0.010

s

130.000 Stop ramp

• Initialisation: 1.000 s

C03579

-2147483647

2147483647 State

• Display of the bit-coded output

signal dnState.

C03582

-214748.3647

unit

214748.3647 Speed at the output

• Read only

• Is generated from the speed

signal dnSpeedOut_s.

C03583

-214748.3647

unit

214748.3647 External master speed at the input

• Read only

• Is generated from the speed

signal dnExtMaster_s.

Advertising