9400 Technology applications | Electronic gearbox

Short setup

Step 2: Parameterising the application

Master value processing

1. Set feed constant (C03932).

– For the master value: Vk = d

1

* π = 471.2389 mm

2. Set the selection "mm" as path unit (C03933).
3. Set the gearbox ratio for the master value as a quotient (numerator and denominator):

i

1

= 3.333 = 10/3

– Numerator (C03930) = 10
– Denominator (C03931) = 3

4. Set the max. machine speed as reference speed (C03941):

– v

max

= 100 m/min = 166.6667 mm/s

Tip!
For operation with a virtual master the following setting of the gearbox ratio is

recommended to achieve a good resolution of the guiding angle/master value:
• Numerator (C03930) = 100
• Denominator (C03931) = 1

Go to dialog:

Overview

Electronic gearbox

Master value processing

Note!

All controllers in the network must have the same master value processing

settings!