2 machine parameters, 9400 technology applications | electronic gearbox – Lenze E94AxHE Technology Application Electronic gearbox User Manual

Page 37

Advertising
background image

EDS94TA10030xxxx EN 1.2 - 11/2009

L

37

9400 Technology applications | Electronic gearbox

Parameter setting & configuration

Machine parameters

5.2

Machine parameters

The following schematic diagram shows the relevant global data (machine parameters) for

the interconnection via the electrical shaft:

[5-2]

Schematic diagram of the most important machine parameters

Detailed information for setting the machine parameters can be obtained from the

following subchapters.

n

Master axis (here: master value encoder as real master)

o

Slave axis 1

p

Slave axis 2

q

Digital frequency cascade (digital frequency extension module required)

d

d

1

3

i

1

i

3

l

1

v

max

Ž

Œ

d

2

i

2



Slave

Master/Slave

Digital

frequency



Symbol

Description

i

1

Gearbox ratio of master value encoder

d

1

Diameter of the master roll

l

1

Master value cycle (if available)

v

max

Maximum speed

i

2

, i

3

Gearbox ratio of the slave axes

d

2

, d

3

Diameter of the slave rolls

Advertising