8 using the "virtual master" function, 9400 technology applications | electronic gearbox – Lenze E94AxHE Technology Application Electronic gearbox User Manual

Page 34

Advertising
background image

9400 Technology applications | Electronic gearbox

Short setup

Using the "Virtual master" function

34

L

EDS94TA10030xxxx EN 1.2 - 11/2009

4.8

Using the "Virtual master" function

Instead of a real master, you can also use a "virtual master" for operating the electronic

gearbox. In this case, one drive in the network acts both as a (virtual) master and the first

slave drive. The master value generated by the "Virtual master" function in the TA is

transferred to the other slave drives via the digital frequency output:

[4-4]

Schematic diagram

Based on the previously described short setup, the following additional settings have to be

made for the master drive for using the "Virtual master" function:

1. Select "Virtual master" as master value source (C03052) in the Overview dialog level.
2. Click Virtual master to change to the dialog level OverviewVirtual master.

n

Virtual master/slave 1

o

Slave 2

p

Digital frequency cascade (digital frequency extension module required)

3 x AC 400 V

i

Slave

Master/Slave

d

1

i

1

2

Œ



Ž

Digital

frequency

d

2

Advertising