14 application error messages, 9400 technology applications | electronic gearbox – Lenze E94AxHE Technology Application Electronic gearbox User Manual

Page 63

Advertising
background image

EDS94TA10030xxxx EN 1.2 - 11/2009

L

63

9400 Technology applications | Electronic gearbox

Parameter setting & configuration

Application error messages

5.14

Application error messages

For the output of application-specific error messages an FB instance ApplicationError of the

function block L_DevApplErr is available in the network.

Via the 8 boolean inputs up to 8 different application error messages with

parameterisable module ID, error ID and error response can be activated by the

application.

The first four inputs can be connected to the multiplexer parameters with the desired

tripping signals. The next four inputs are firmly connected to the tripping signals of the

application.

Parameter setting: Tab All parameters

Error message

Error ID

Error response

1

Free (configurable via C03060/1)

8001

No response

2

Free (configurable via C03060/2)

8002

Error

3

Free (configurable via C03060/3)

8003

Error

4

Free (configurable via C03060/4)

8004

Error

5

Following error

8005

Warning

6

Drive cannot follow

8006

Warning

7

Drive system interrupted

8007

Quick stop by trouble

8

External fault in drive system

8008

Quick stop by trouble

Parameter

Lenze setting

C05900

Module ID

999

C05901/1...8

Error ID 1 ... 8

See table above

C05902/1...8

Error response 1 ... 8

See table above

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

FALSE  Application fault 1

C03060/1

FALSE  Application fault 2

C03060/2

FALSE  Application fault 3

C03060/3

FALSE  Application fault 4

C03060/4

Advertising