16 parameterisable function blocks, 1 applicationerror, 9400 technology applications | electronic gearbox – Lenze E94AxHE Technology Application Electronic gearbox User Manual

Page 68

Advertising
background image

9400 Technology applications | Electronic gearbox

Parameter setting & configuration

Parameterisable function blocks

68

L

EDS94TA10030xxxx EN 1.2 - 11/2009

5.16

Parameterisable function blocks

This subchapter lists all relevant parameterisable function blocks of the technology

application and the corresponding parameters in alphabetical order.

5.16.1

ApplicationError

Is an instance of

Function

L_DevApplErr

Error handling



Application error messages ( 63)

Parameter

Possible settings

Information

C05900

980

999 Module ID

• Initialisation: 999

C05901/1...8

0

65535 Error ID

• Initialisation: 8001 ... 8008

C05902/1...8

Error response

0 None
1 Fault
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information

Advertising