5.16.5

FollowError_Hysteresis

5.16.6

FollowError_Limit

5.16.7

HomingSetPosition

Is an instance of

Function

L_SdSetPosition

Conversion of the following error hysteresis selected in the real units of the machine

via C03916 into a position in [increments].



Following error monitoring ( 53)

Parameter

Possible settings

Information

C03916

-214000.0000

unit

214000.0000 Position value

• Initialisation: 0.5000 units

C03917

Character string

Position unit

• Read only

C03918

-2147483647

2147483647 State

• Read only

Is an instance of

Function

L_SdSetPosition

Conversion of the following error limit selected in the real units of the machine via

C03911 into a position in [increments].



Following error monitoring ( 53)

Parameter

Possible settings

Information

C03911

-214000.0000

unit

214000.0000 Position value

• Initialisation: 1.0000 units

C03912

Character string

Position unit

• Read only

C03913

-2147483647

2147483647 State

• Read only

Is an instance of

Function

L_SdSetPosition

Conversion of the home position selected in the real units of the machine via C03012

into a position in [increments].



"Homing" mode ( 49)

Parameter

Possible settings

Information

C03012

-214000.0000

unit

214000.0000 Position value

• Initialisation: 100.0000 units

C03013

Character string

Position unit

• Read only

C03014

-2147483647

2147483647 State

• Read only