4 setpoint conditioning, 9400 technology applications | electronic gearbox – Lenze E94AxHE Technology Application Electronic gearbox User Manual

Page 48

Advertising
background image

9400 Technology applications | Electronic gearbox

Parameter setting & configuration

Operating mode "Electronic gearbox"

48

L

EDS94TA10030xxxx EN 1.2 - 11/2009

5.4.4

Setpoint conditioning

[5-8]

"Setpoint conditioning" function in the signal flow (schematic diagram)

This function is used for speed ratio between the master shaft and the machine axis.

Parameter setting: Tab All parameters  Category Electronic gearbox

ConvertElShaftMotor

Configuration: Tab FB editor  FB

ConvertElShaftMotor

n

Master value with trimming

o

Actual value

M

v

Slave

Real master/

Virtual master

v

t

Dv

C03006 = 1

Œ



Parameter

Lenze setting

Value Unit

C03715

Operating mode

Unit coupling

C03717/1

Reference variable X

1.0000

C03717/2

Reference variable Y

1.0000