MTS Acumen User Manual

Page 50

Advertising
background image

Note: The red indicators above are typical of a tripped E-Stop.

Status Panel

Corrective Action

Error

Status Indicator

Item

See individual status information.

Active items in this
category cause power to

Power

1

be removed from the
main actuator and lift
system.

If no safety faults are active, verify that the
Emergency-Stop button on the

The Emergency-stop
circuit is active.

E-stop

2

frame-mounted control is cleared. Also verify
that the remote Emergency-Stop button is
cleared or that a jumper plug is installed in
its place.

See individual status information.

Active items in this
category indicate that a

Safety fault

3

safety-related fault has
occurred.

Verify that the Remote/Accessory
Emergency-Stop cable is attached securely.

The accessory safety
relay monitored state

Accessory
E-stop/safety relay
status

4

If a remote Emergency-Stop is not used,
check that a jumper plug is installed in its
place.

does not match
commanded state.

Shut down the software and cycle power to
the frame to reset this fault status. If the fault
persists, contact MTS Technical Support.

50 | MTS Acumen

System Introduction

Advertising