1–2

Overview

Publication 1203–5.9 –– October 1996

Your SLC processor or rack adapter determines what functions are
available for the SLC to SCANport module.

If the device in the left hand slot

of the SLC chassis is a:

Is basic mode

supported?

Is enhanced mode

supported?

Fixed style controller (using an
expansion rack)

Yes

No

SLC 5/01 controller

Yes

No

SLC 5/02, 5/03, or 5/04 controller

Yes

Yes

1747–OC open controller

Yes

Yes

Any SLC rack adapter

Yes

No

Future SLC product offerings may support enhanced mode

communication.

The following table provides information about basic mode and
enhanced mode.

Function

Basic

Mode

Enhanced

Mode

Maximum number of words of I/O per
SCANport device

2

10

Total number of words of I/O for module

8

32

16–bit Logic Command (to SCANport device)

Yes

Yes

16–bit Logic Status (from SCANport device)

Yes

Yes

16–bit Reference (to SCANport device)

Yes

Yes

16–bit Feedback (from SCANport device)

Yes

Yes

Datalinks

No

Yes

Safe State Data

No

Yes

Messaging

No

Yes