Save Parameter Values to Non–volatile Storage

The Save Parameter Values to Non–volatile Storage message lets you
save the values of all parameters to non–volatile storage. The
following is an example of this request:

Service=Save to Storage

Parameter Class

Instance

Attribute

Data Length=0 Bytes

M0:e.000

M0:e.001

M0:e.002

M0:e.003

M0:e.004

0016

000f

0000

0000

0000

Value

Save Parameter Values to Non–Volatile Storage

Service=Save to Storage

Parameter Class

Instance

Attribute

Data Length=0 Bytes

M1:e.100

M1:e.101

M1:e.102

M1:e.103

M1:e.104

0016

000f

0000

0000

0000

Value

Response

Figure B.11 shows a Save Parameter Values to Non–volatile Storage
request. This message has successfully saved all SCANport device
parameters from RAM to non–volatile storage.

Figure B.11
Example of Save Parameter Values to Non–volatile Storage

address 0 1 2 3 4 5 6 7 8 9
N10:0 0016 000f 0000 0000 0000 0000 0000 0000 0000 0000

address 0 1 2 3 4 5 6 7 8 9
N11:0 0016 000f 0000 0000 0000 0000 0000 0000 0000 0000