SCANport Messaging

B–28

Publication 1203–5.9 –– October 1996

Write Parameter Link from Parameter Number

The Write Parameter Link from Parameter Number message lets you
write the parameter link information for a specific parameter. The
following is an example of this request:

Service=Set Attribute Single

Internal A–B Vendor Specific Class

Instance=Parameter #5

Attribute=Link

Data Length=2 Bytes

M0:e.000

M0:e.001

M0:e.002

M0:e.003

M0:e.004

0010

0099

0005

0000

0002

Value

Write Parameter Link to Parameter Number 5

Service=Set Attribute Single

Internal A–B Vendor Specific Class

Instance=Parameter #5

Attribute=Link

Data Length=0

M1:e.100

M1:e.101

M1:e.102

M1:e.103

M1:e.104

0010

0099

0005

0000

0000

Value

Response

Link Number

M0:e.005

0007

Figure B.20 shows a Write Parameter Link from Parameter Number
request. This example is a write to the link value of parameter 5 (the
parameter number is in N10:2). The link value being written is 6.

Figure B.20
Example of Write Parameter Link from Parameter Number

address 0 1 2 3 4 5 6 7 8 9
N10:0 0010 0099 0005 0000 0002 0006

address 0 1 2 3 4 5 6 7 8 9
N11:0 0010 0099 0005 0000 0000